TABLE I, add:
“ ~ K--- [ -55 to +125 \. O
● 75 I * .18% of raxim.. ratsd value or I
I .03 pF (whichever is greater). I”
PAGE 3
3.6: DeLete in its entirety.
PAGE 5
I
3.26, line two: Delete ,,source cedes” and substitute “ lot codes”.
I
* 3.27.1, delete in its entirety and substitute:
0S3.27. 1 Solderi nq. where soldering js
●mployed in the construction of capacitors, only fluxes with Lou
corrosive properties sha lL be used, unless i t can be shown that corrosive elements have been satisfactory LY
removed after soldering. Al 1 excess flux and solder shal 1 be refmved. Electrical connections sha 11 be
electrical lY cent inuous after soldering and, where possible, mechani caLLY secure before solder ing. ”
PAGE 7
TA8LE II, first column: Group 1, delete “Burn-in” test and a L1 relat~ data.
PAGE 8
I
TABLE 1{1, first c.alunm: Delete ‘Wm. in” test and al 1 rebstsd dnta.
PAGE 9
TABLE v< test column: subgroups 111 and V, delete “II”.
TABLE v, test column: subgroup 111, add “?I”.
TABLE V: After table V, add “~1 ELectri Cal tests are c-at requi red on unsea LHl UnitS. ”
PAGE 10
4.6.2: Delete in its entirety.
AMSC NIA
10f4