DISTRIBUTION A. Approved for public release; distribution unlimited.
EN-SB-08-012 Rev. C, Page 1 of 35
Number: EN-SB-08-012, Revision D
Date: February 2018
Subject: In-Service Inspection Crack Size Assumptions for Metallic Structures
References:
1. MIL-STD-1530D, Aircraft Structural Integrity Program, 13 October 2016.
2. JSSG-2006, Department of Defense Joint Service Specification Guide, Aircraft Structures,
30 October 1998.
3. MIL-HDBK-1823A, Nondestructive Evaluation System, Reliability Assessment, 7 April 2009.
4. J. Brausch, L. Butkus, D. Campbell, T. Mullis and M. Paulk, Recommended Processes
and Best Practices for Nondestructive Inspection of Safety-of-Flight Structures, AFRL-ML-
WP-TR-2009-4373, Air Force Research Laboratory, Wright-Patterson AFB, OH, Oct 2008.
5. EZ-SB-15-002, Requirements for NDI Procedure Development, Validation and Verification
for Aircraft Structural Inspections During Operations and Support Phase.
6. T.O. 33B-1-2, Nondestructive Inspection General Procedures and Process Controls.
7. T.O. 33B-1-1, Nondestructive Inspection Methods, Basic Theory.
8. D. Palumbo, Probability of Detection Studies for Nondestructive Inspection Facilities Final
Report, Contract Number F09603-01-D-0207, Karta Technologies, San Antonio, TX, 31
March 2006.
9. Ripudaman Singh, Three Decades of NDI Reliability Assessment, Report No. Karta-3510-
99-01, Karta Technologies, San Antonio, TX 78249, May 2000.
10. W. H. Lewis, B.D. Dodd, W.H. Sproat, J.M. Hamilton, Reliability of Nondestructive
Inspections – Final Report, Lockheed-Georgia Co, Report No. SA-ALC/MME 76-6-38-1, Dec
1978.
11. D. Palumbo, D Earnest, Probability of Detection (POD) Studies for Nondestructive Inspection
(NDI) Facilities Revision to Final Report, contract number: F09603-01-D-0207-SD05, Karta
Technologies, San Antonio, TX 78249.3 Oct 2005.
12. M. Bode, F. Spencer, Air Force Research Lab Quality Assurance Proficiency Assessment
Final Report, Sandia Laboratories, Albuquerque, NM, July 2007.
13. J. Brausch, Capability Estimation for Rotary Bolt hole Eddy Current Inspection of Titanium,
Report Number AFRL/RXS 08-047, June 2008.
14. J. Brausch, Capability Estimation for Rotary Bolt hole Eddy Current of Aluminum Structures,
Report Number AFRL/RXS 08-068, Sept 2008.
AFLCMC/EZ
Bldg 28, 2145 Monahan Way
WPAFB, OH 45433-7017
Phone 937-255-5312